July 13, 1994
Before: Type I anchors, 3,150 / 4,725. After: Type II, 4,000 / 6,000. Also the day Zone III counties were split off.
Florida · FLHSMV
0/8 lessons marked
Study aid, not a substitute for the class
Built from the FLHSMV installer page, Florida Statute 320.8249, Rule Chapter 15C-1, and the department’s installer training manual (revised April 2009). Numbers below are the ones the course drills. If a manufacturer’s manual is stricter, the manual wins. If the rule is stricter, the rule wins. Recheck flrules.org before a job or an exam — chapters get amended.
Before: Type I anchors, 3,150 / 4,725. After: Type II, 4,000 / 6,000. Also the day Zone III counties were split off.
HUD labels and data plates begin. Hurricane-resistant homes after this date, with no factory roof ties, do not get over-the-roof ties added.
Diagonal frame ties no farther than 5 ft 4 in. An anchor within 2 ft of each end. Same 2 ft for the first pier and for end centerline ties.
Florida I-beam clearance is 18 inches. On a slope, never under 12. Do not use another state’s 12-inch HUD minimum.
Sources: FLHSMV Mobile Home Installer page and FAQ; §320.8249, Fla. Stat.; Rules 15C-1.0101 through 15C-1.0107 and 15C-2.0073, F.A.C.; FLHSMV Installer Training Manual, rev. 04/09; 24 CFR 3280.305 wind-zone counties. This is a study aid, not a legal opinion and not permission to install without the license, the permit, and listed hardware.